Nebulae I HIGH FLOW Laparoscopic Insufflation System

CO2 Insufflation for all minimally invasive laparoscopic, surgical procedures

  • High Performance: HIGH FLOW ( Up to 50 LPM through either port )
  • Gas Warming: Warms CO2 to reduce the chill effect for faster patient recovery
  • Dual Port: CO2 delivery from up to two ports when higher demand for CO2 is required
  • Automatic and Mechanical Pressure Relief for greater patient safety
  • The TAP™ Feature: A proprietary, independent method for directly measuring abdominal pressure. The benefits are faster, initial insufflation and faster recovery from sudden leaks. Reduces the “breathing effect” common to standard insufflation.
  • Integrates with video tower systems and automatically adjusts to low and high pressure CO2 gas supplies
  • Communicates with centralized OR communications systems
  • Does not require the use of a non-standard tubing sets and trocar sleeves to implement flow rates above 20LPM
6-810-00 Warmer Controller (100-240 VAC)
In-Line Warmer Assembly Cable (non-sterile)

4 pin configuration CO2 gas warmer and cable for use on 6-800-00 stand alone warmer controller unit. This reusable assembly connects to any disposable insufflation tubing set.

6-820-00 In-Line Warmer Assembly Cable
In-Line Warmer Assembly Cable (non-sterile)

8 pin configuration CO2 gas warmer and cable for use on NORTECH® manufactured laparoscopic insufflators with gas warmer feature. This reusable assembly connects to any disposable insufflation tubing set.

66-54020-0 Metal CPC to Hose Barb Style Out connector

Metal CPC to Hose Barb Style Out-Put Port Adapter for use on insufflators with a CPC style gas out-put port. Sold non-sterile
Qty: 1

66-54030-0 Metal CPC to Female Luer Out connector

Metal CPC to Female Luer Out-Put Port Adapter for use on insufflator with a CPC style gas out-put port. Sold non-sterile
Qty: 1

66-54040-0 Metal CPC to ISO Large Mouth Style Out connector

Metal CPC to ISO Large Mouth Style Out-Put Port Adapter for use on insufflator with a CPC style gas out-put port. Sold non-sterile
Qty: 1

7-510-09 High Pressure Hose & CO2 Yoke

High Pressure Hose & CO2 Yoke. Connects insufflator to CO2 metal gas source cylinder bottles.

7-510-34 High Pressure Hose with DISS Connector

High Pressure Hose with DISS Connector. Connects insufflators to main hospital supply source for CO2. (Hose assembly complete)

7-510-36 High Pressure Hose with DIN477

High Pressure Hose with DIN477 Connector.
For Insufflator to German / European CO2 connection.
Connects the European gas bottle to the insufflator.

7-510-50 Shuttle Valve System

Shuttle Valve System

The shuttle valve, high pressure hose and yoke system was designed to be used with laparoscopic insufflators to reduce the likelihood of running out of insufflation gas
(“NO GAS” Condition) during a laparoscopic surgical procedure.

Connect 2 tanks of CO2 gas at the same time

7-650-00 product image of Nebulae I

Nebulae I Laparoscopic Insufflator

  • 50 liters per minute flow
  • Variable Pressure Relief
  • CO2 gas source recognition, cylinder or wall supply
  • Gas Warming
  • Dual Port
  • TAP™ True Abdominal Pressure Sensing

The Nebulae I Insufflator uses the following accessories
(Sold Separately)

  • # 7-510-52 General Use, Filtered Insufflation Tubing
  • # 7-510-31 TAP™ Tubing for pressure sense
  • # 6-820-00 Warmer Assembly Cables (2 Recommended)

 

Private Label Inquires Welcome

 

 

9-003-00 Universal Power Cord

Universal Power Cord for use in the U.S.

Disposable Insufflation Tubing Sets and TAP™ Tubing for separate pressure sensing

Sold Sterile, 10 sets per box.
Each set contains special HIGH FLOW componants and a HIGH FLOW filter that traps particles down to 0.1 micron in size.

Choose the connector style that fits your insufflator

7-510-15 7-510-15

Fits “inside” the large mouth, gas output port fitting of the WOLF, STORZ and LINVATEC insufflators

7-510-16 7-510-16

For use on most older style insufflators with lower flow rates. Luer fittings are at both ends of the tubing set.

7-510-28 7-510-28

Fits NORTECH®, older style OLYMPUS, SNOWDEN PENCER, SMITH & NEPHEW, CONMED-LINVATEC and ACMI Insufflators

7-510-31 7-510-31

The TAP™ Tubing Set
Has luer connectors at both ends. For use with Nortech insufflators that offer the TAP™ feature for true abdominal pressure sensing. Provides a faster fill time for recovery of a lost pneumoperitoneum and reduces the noticeable breathing effect common to standard laparoscopic insufflation.

7-510-32 7-510-32

Fits over the hose barb style output ports found on OLYMPUS, older STORZ and STRYKER insufflators

7-510-46 7-510-46

Fits “over” the large wide mouth, gas output port fitting on older style Linvatec insufflators